www.majority.nl   Questions? Feedback?    E-mail in Dutch, English or German (preferred order) to m.majoor@majority.nl

Navigation

Home
Various
DCC600 Service mode

Projects
  Miscellaneous
  Remote control
  DVB
  BenchScope

TV
  Main
  Miscellaneous
  Chassis list
  28PW9525 Remote control
  Pioneer KRL-32V service mode

TV Service mode
  Matchline (generic)
  Remote control codes
  MG7.1E Customer Service Mode
  MG7.1E Service Alignment Mode
  MG7.1E Service Default Mode

TV Service mode tables
  A10
  EM
  EM1
  EM2
  FJ3.0
  GFL
  L01
  MG2
  MG3
  MG7


Revision history
   
- -
     
DCC600 Service mode

To put the DCC600 recorder into service mode you have to press the following keys simultaneously on the recorder itself:
  DOLBY NR B/C  +  REC.PAUSE  +  PLAY

Depending if there is a cassette in the tray you are either now in the System Hardware Check mode (no cassette) or in Data Error Processing mode (with cassette). When in Data Processing Mode you have realtime information of the data processing (playback only).

In the System Hardware Check mode you get the message 'SERVMODE V77' on the display. You now have two ways to go using either the PREV or NEXT key.

NO TAPE + DOLBY NR B/C + REC.PAUSE + PLAY
PREV FACTORY MODE MARK WRITE KEY TEST For each pressed key the keycode is displayed
MARK ERASE QUARTZ TEST
RENUMBER CHECK COND..
DIG./ANALOG DISPLAY TEST Press FORWARD multiple times to check different display items
DOLBY NR B/C IRTST Infrared test.
Displays the received infrared code.
NOTE: while the IRTST is active the tray is continuously being extended (with the motor on!) so it is better to use the IRTST from SERVICE MODE instead of FACTORY MODE
REC.PAUSE NF IN TEST
APPEND TRAY TEST Use OPEN/CLOSE to open and close the tray
NEXT SERVICE MODE MARK WRITE KEY TEST For each pressed key the keycode is displayed
DIG./ANALOG DISPLAY TEST Press FORWARD multiple times to check different display items
DOLBY NR B/C IRTST Infrared test. Displays the received infrared code.
NOTE: different from the FACTORY MODE (the tray is not activated)
TEXT LT CHECK Press FORWARD to initiate the following checks:
DEQ CHECK
DDSP CHECK
ADAS/SBC CHECK
They should all respond with an OK result
TIME MAINVERS V75
APPEND TRAY TEST Use OPEN/CLOSE to open and close the tray

You use the STOP key to exit (step back into) the modes.

www.majority.nl   Questions? Feedback?    E-mail in Dutch, English or German (preferred order) to m.majoor@majority.nl